Ultrafast force-clamp spectroscopy of single molecules reveals load dependence of myosin working stroke.

Capitanio M, Canepari M, Maffei M, Beneventi D, Monico C, Vanzi F, Bottinelli R, Pavone FS
Nature methods 2012 doi:10.1038/nmeth.2152 PubMed
Optical tweezers

Biological system

Data availability

Not checked (no full text)

Abstract

We describe a dual-trap force-clamp configuration that applies constant loads between a binding protein and an intermittently interacting biological polymer. The method has a measurement delay of only ∼10 μs, allows detection of interactions as brief as ∼100 μs and probes sub-nanometer conformational changes with a time resolution of tens of microseconds. We tested our method on molecular motors and DNA-binding proteins. We could apply constant loads to a single motor domain of myosin before its working stroke was initiated (0.2-1 ms), thus directly measuring its load dependence. We found that, depending on the applied load, myosin weakly interacted (<1 ms) with actin without production of movement, fully developed its working stroke or prematurely detached (<5 ms), thus reducing the working stroke size with load. Our technique extends single-molecule force-clamp spectroscopy and opens new avenues for investigating the effects of forces on biological processes.