Nonlinearly additive forces in multivalent ligand binding to a single protein revealed with force spectroscopy.

Ratto TV, Rudd RE, Langry KC, Balhorn RL, McElfresh MW
Langmuir : the ACS journal of surfaces and colloids 2006 doi:10.1021/la052087d PubMed
Force spectroscopy

Results

ObservableValueSource sentence
Rupture force85 pNSpecifically, the most common rupture forces are approximately 46, 68, and 85 pN at a loading rate of 650 +/- 25 pN/s, which we argue
Loading rate650 ± 25 pN/smon rupture forces are approximately 46, 68, and 85 pN at a loading rate of 650 +/- 25 pN/s, which we argue corresponds to 1, 2, and 3 ligands being pulled simult

Auto-extracted; verify against the paper before reuse.

Data availability

Not checked (no full text)

Abstract

We present evidence of multivalent interactions between a single protein molecule and multiple carbohydrates at a pH where the protein can bind four ligands. The evidence is based not only on measurements of the force required to rupture the bonds formed between concanavalin A (ConA) and alpha-D-mannose but also on an analysis of the polymer-extension force curves to infer the polymer architecture that binds the protein to the cantilever and the ligands to the substrate. We find that although the rupture forces for multiple carbohydrate connections to a single protein are larger than the rupture force for a single connection, they do not scale additively with increasing number. Specifically, the most common rupture forces are approximately 46, 68, and 85 pN at a loading rate of 650 +/- 25 pN/s, which we argue corresponds to 1, 2, and 3 ligands being pulled simultaneously from a single protein as corroborated by an analysis of the linkage architecture. As in our previous work polymer tethers allow us to discriminate between specific and nonspecific binding. We analyze the binding configuration (i.e., serial vs parallel connections) through fitting the polymer stretching data with modified wormlike chain (WLC) models that predict how the effective stiffness of the tethers is affected by multiple connections. This analysis establishes that the forces we measure are due to single proteins interacting with multiple ligands, the first force spectroscopy study that establishes single-molecule multivalent binding unambiguously.